CE Certification Efficient Gas Thermal Hot Oil Heater

CE Certification Efficient Gas Thermal Hot Oil Heater

Wilford offers safe, fully automated , low consumptionCEYY(Q)W GASHEATING-CONDUCTION BOILER, our company is a successful manufacturer and supplier, we have devoted ourselves to boilers many years, we will provide excellent service and competitive price for you, we are expecting to become your long-term partner in China.

Product Details

CE YY(Q)W Gas Heating-conduction Boiler

Description

Unit

600(50)

850(75)

1200(100)

1400(125)

1800(150)

2400(200)

3500(300)

4100(350)

6000(500)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Y(Q)

Rated thermal power

KW

600

850

1200

1400

1800

2400

3500

4100

6000

Heating efficiency (≥%)

%

90

90

90

92

92

92

92

92

92

Design pressure

Mpa

1

1

1

1

1

1

1.1

1.1

1.1

Medium highest temperature

350

350

350

350

350

350

350

350

350

Medium capacity of boiler

0.4

0.52

0.76

0.95

1.48

2.1

2.4

2.53

6.1

Medium circulation  volume

m³/h

80

80

100

100

160

200

200

200

300

DN of oil outlet

DN

100

100

125

125

150

200

200

200

250

Whole system installed capacity

Oil

KW

30

40

40

45

50

70

70

70

150

Gas

KW

30

40

40

45

50

70

70

70

150

Total weight of equipment

KG

3530

4500

5600

6200

9500

10500

13500

16065

28850

External dimension

Length

mm

3650

4100

5500

5700

5900

6500

8000

8200

9000

Width

mm

1500

1700

2100

2100

2100

2300

2400

2500

3200

Height

mm

1870

2100

2400

2400

2550

2750

2900

3000

3600

Transport dimension

Length

mm

3250

3800

4600

4850

5100

5800

6800

7200

7800

Width

mm

1500

1700

2100

2100

2100

2300

2400

2500

3200

Height

mm

1870

2100

2400

2400

2550

2750

2900

3000

3600

Wilford could provide customized products with specific power supply in the world.

CE YY(Q)W Gas Heating-conduction Boiler produt introduction

1 High-quality heat source

Under normal pressure, the oil-conducting heating system in liquid phrase can output hot oil of maximum 350 centigrade degree for the heat user. Our oil-conducting heating system applied the Fuji temperature control instrument and intelligent self-turning temperature control technology (PID).The precision of control technology is up to about 1 centigrade degree, which can be accurately controlled in the range of the used temperature. The main power for heating uses non-contact switch circuit which is the solid state in order to adapt to the frequent switching, and which has no interference to the power supply. And it has the function of anti-dry. The cooling system for hot oil can be designed according to the end user requirement, so that it can satisfy the process requirement of rapid cooling after heating up.

2 Energy saving, low operating cost

Oil- conducting heating system is closed cycle in the liquid phrase. The difference of temperature between the output oil and the return oil is within the range of 20-30 centigrade degree. That is to say only to heat a temperature difference of 20-30 centigrade degree can the working temperature be reached. Meanwhile, no water treatment equipment is required for this device. No lose of slam running, steam reeking, dropping and leakage as the steam boiler. The ratio of heating utilization is very high. It can save about 30% energy compared with the steam boiler.

3 Low investment of equipment

Due to the reason that the system of oil-conducting heating system is simple, no water treatment equipment, no more auxiliary equipment, and low pressure bore by the boiler, the investment for the whole system is comparatively low.

4 Safety

Because the system only withstands the pump pressure and it has no explosion risk, it is more secured.

5 Environmental protection

The environmental effect of the organic heater carrier heating system is mainly reflected in the minimal fume emission, no sewage pollution and no thermal pollution.

6 Widely application

It can be applied in the following areas: high-temperature shaping, plate heating, rubber, drying, dyeing and printing, chemical industry, plywood production, rolled water-proof material production, asphalt heating, non-woven hot-rolled machine, fiber, glass hot press machine, reactor, mould, drying room, oven, and other heating industries.


As one of the leading and professional ce certification efficient gas thermal hot oil heater manufacturers, WILFORD now brings you the best quality and highly precise equipment from its professional factory. We have advanced equipment and technology at your service, please rest assured to buy.

Related Products
Quick Navigation
  • About Us
  • Products
  • News
  • Exhibition
  • Contact Us
  • Feedback
  • Newsletter
    Enter in your email address to receive deals and coupons.
    86-512-58170166
    86-512-58698850 manager@wilfordboiler.com