Before The Operation Of Hot Water (steam) Boiler, An Indispensable Water Pressure Test
Mar 14, 2017

Gas (vapor) hot water boiler boiler parts after group on for the installation of the finished product, after a long distance transportation, loading and unloading, installation, hard to avoid collisions and damage, so the need for a water pressure test after installation. Practice has proved that through the defect in the hydrostatic test can find boiler rear adopt corresponding measures in time to ensure the safety of operation.

Boiler water pressure test, general component is the rated working pressure of hydrostatic test and super hydrostatic test, boiler body overpressure test pressure is 1.25 times the rated working pressure of the pot shell or the rated pressure of 0.4 MPa.


One, when you meet the one of the following situations require the overpressure hydrostatic test:

1. The newly installed boiler before starting the related;

2. boiler pressure parts after a major renovation or replacement;

3. The operation of the boiler every six years on a (combining) after overhaul.Two, in the following circumstances, the need to work pressure hydraulic test:

1. general, repair or repair after the boiler pressure test work pressure in the maintenance after;

2. for more than 30 days of standby, the hydraulic pressure test shall be done before ignition;


During the hydrostatic test, need to have qualified personnel shall be carried out in accordance with the standard process

Specific operation method and the matters needing attention, pay attention to WeiFu official website or electric WeiFu hotline, have a professional solution for you.